National Building Code of the Philippines
PD 1096 · 1977 · Building and construction law
Source checked. This copy does not establish whether a provision is current, amended, or controlling. Extracted text may contain scanning errors; compare it with the original.
TEXT SEGMENT 14 / 27
(5.1)
Stair Rise and Run
The maximum rise of treads shall not exceed 200 millimeters and the minimum width of the run shall be 280 millimeters. The maximum variation in the width of treads in any one flight shall not be more than 5 millimeters and the maximum variation in one height of two adjacent rises shall not exceed 5 millimeters.
(5.2)
Ramp Slope
The slope of a ramp shall not exceed 1 in 8. Ramps shall be roughened or shall be of approved nonslip material.
(5.3)
Handrails
A ramp with a slope exceeding 1 in 10 shall have handrails. Stairs for stands shall have handrails. Handrails shall conform to the requirements of this Code.
(6)
Guardrails
(6.1) Guardrails shall be required in all locations where the top of a seat plank is more than 1.20 meters above the grade and at the front of stands elevated more than 600 millimeters above grade. Where only sections of stands are used, guardrails shall be provided as required in this Code.
(6.2) Railings shall be 1.10 meters above the rear of a seat plank or 1.10 meters above the rear of the steps in the aisle when the guardrail is parallel and adjacent to the aisle: Except, that the height may be reduced to 900 millimeters for guardrails located in front of the grandstand.
(6.3) A midrail shall be placed adjacent to any seat to limit the open distance above the top of any part of a seat to 250 millimeters where the seat is at the extreme end or at the extreme rear of the bleachers or grandstand. The intervening space shall have one additional rail midway in the opening: Except, that railings may be omitted when stands are placed directly against a wall or fence giving equivalent protection; stairs and ramps shall be provided with guardrails. Handrails at the front of stands and adjacent to an aisle shall be designed to resist a load of 75 kilograms per linear meter applied at the top rail. Other handrails shall be designed to resist a load of 40 kilograms per linear meter.
(7)
Foot Boards
Footboards shall be provided for all rows of seats above the third row or beginning at such point where the seating plank is more than 600 millimeters above grade.
(8)
Exits
(8.1)
Distance to Exit
The line of travel to an exit shall not be more than 45.00 meters. For stands with seats without backseats this distance may be measured by direct line from a seat to the exit from the stand.
(8.2)
Aisle Used as Exit
An aisle may be considered as only one exit unless it is continuous at both ends to a legal building exit or to a safe dispersal area.
(8.3)
Two Exits Required
A stand with the first seating board not more than 500 millimeters above grade of floor may be considered to have two exits when the bottom of the stand is open at both ends. Every stand or section of a stand within a building shall have at least two means of egress when the stand accommodates more than 50 persons. Every open air stand having seats without backrest shall have at least two means of egress when the stand accommodates more than 300 persons.
(8.4)
Three Exits Required
Three exits shall be required for stands within a building when there are more than 300 occupants within a stand and for open air stands with seats without backrests where a stand or section of a stand accommodates more than 1000 occupants.
(8.5)
Four Exits Required
Four exits shall be required when a stand or section of a stand accommodates more than 1000 occupants:
Except
, that for an open air stand with seats without backrests four exits need not be provided unless there are accommodations for more than 3000 occupants.
(8.6)
Width
The total width of exits in meters shall not be less than the total occupant load served divided by 165: Except, that for open air stands with seats without backrests the total width of exits in meter shall not be less than the total occupant load served divided by 500 when existing by stairs, and divided by 650 when existing by ramps or horizontally. When both horizontal and stair exits are used, the total width of exits shall be determined by using both figures as applicable. No exit shall be less than 1.10 meters in width. Exits shall be located at a reasonable distance apart. When only two exits are provided, they shall be spaced not less than one-fifth of the perimeter apart.
(9)
Securing of Chairs
Chairs and benches used on raised stands shall be secured to the platforms upon which they are placed: Except, that when less than 25 chairs are used upon single raised platform the fastening of seat to the platform may be omitted. When more than 500 loose chairs are used in connection with athletic events, chairs shall be fastened together in groups of not less than three, and shall be tied or staked to the ground.
(10) Safe Dispersal Area
Each safe dispersal area shall have at least two exits. If more than 6000 persons are to be accommodated within such an area, there shall be a minimum of three exits, and for more than 9000 persons there shall be a minimum of four exits. The aggregate clear width of exits from a safe dispersal area shall be determined on the bases of not less than one exit unit of 600 millimeters for each 500 persons to be accommodated and not exit shall be less than 1.10 meters in width, a reasonable distance apart that shall be spaced not less than one-fifth of the perimeter of the area apart from each other.
(o)
Special Hazards
(1)
Boiler Rooms
Except in Group A Occupancies, every boiler room and every room containing an incinerator or liquified petroleum gas or liquid fuel-fired equipment shall be provided with at least two means of egress, one of which may be a ladder. All interior openings shall be protected as provided for in this Code.
(2) Cellulose Nitrate Handling
Film laboratories, projection rooms, and nitro-cellulose processing rooms shall have not less than two exits.
SECTION 1208. Skylights.
(a) All skylights shall be constructed with metal frames except those for Groups A and J Occupancies. Frames of skylights shall be designed to carry loads required for roofs. All skylights, the glass of which is set at an angle of less than 45 degrees from the horizontal, if located above the first storey, shall be set at least 100 millimeters above the roof. Curbs on which the skylights rest shall be constructed of incombustible materials except for Types 1 or 11 Construction.
(b) Spacing between supports in one direction for flat wired glass in skylights shall not exceed 625 millimeters. Corrugated wired glass may have supports 1.50 meters apart in the direction of the corrugation. All glass in skylights shall be wired glass: Except, that skylights over vertical shafts extending through two or more storeys shall be glazed with plain glass as specified in this Code:
Provided
, that wire glass may be used in ventilation equal to not less than one-eight the cross-sectional area of the shaft but never less than 1.20 meters is provided at the top of such shaft. Any glass not wire glass shall be protected above and below with a screen constructed of wire not smaller than 2.5 millimeters in diameter with a mesh not larger than 25 millimeters. The screen shall be substantially supported below the glass.