YARD OR PATIO
The vacant space left in a lot between the building and the property line.
YARD, REAR
The yard lying between the side lot lines and the nearest lot line and the nearest building line.
YARD, SIDE
The yard lying between the side line and the nearest building and between the front and the rear yards.
TABLE 708-A. DIMENSION OF WOODEN POSTS OR SUPORTALES
____________________________________________________________________________________________
Type
Building
Maximum
Height of
1st Floor
Maximum
Height
Total
Maximum
Spacing
of Post
Required Maximum
Finished Size
of Suportales
____________________________________________________________________________________________
1-Storey Shed
4.00 M
3.50 M
10 cms. x 10 cms.
1-Storey Shed
3.00 M
4.00 M
10 cms. x 10 cms.
1-Storey Shed
5.00
4.00 M
12.5 cms. x. 12.5 cms.
1-Storey House or
Chalet
1.00 to
5.50 M
3.60 M
12.5 cms. x. 12.5 cms.
2-Storey House
3.00 M
6.00 M
3.00 M
12.5 cms. x. 12.5 cms.
2-Storey House
4.50 M
7.00 M
4.00 M
12 cms. x. 12 cms.
2-Storey House
5.00 M
8.00 M
4.50 M
17.5 cms. x. 17.5 cms.
2-Storey House
9.00 M
4.50 M
20 cms. x 20 cms.
____________________________________________________________________________________________
Log or tree trunk
suportales
may be used as post in
indigenous
traditional type of construction provided that these are of such sizes and spacing as to sustain vertical loading equivalent at least to the loading capacities of the posts and spacing in this Tables.
TABLE 1003-A PROJECTIONS OF BALCONIES AND APPENDAGES
____________________________________________________________________________________________
Width of Streets
Balconies
Total Projections
____________________________________________________________________________________________
Over 3.00 m. but less than 6.00
With Balcony
0.60 m.
6.00 m. to less than 10.00 m.
With Balcony
0.90 m.
10.00 m. up to 11.00 m.
With Balcony
1.00 m.
10.00 m. to less than 11.00 m.
With Balcony
1.10 m.
12.00 m. to less than 13.00 m.
With Balcony
1.30 m.
13.00 m. to less than 14.00 m.
With Balcony
1.40 m.
14.00 m. or over
With Balcony
1.50 m.
____________________________________________________________________________________________
TABLE 1106-A.
TYPE OF PROTECTION REQUIRED FOR PEDESTRIANS
____________________________________________________________________________________________
Height of
Construction
Distance from Construction
Protection
Required
____________________________________________________________________________________________
Eight feet or
less
Less than six feet
Six feet or more
Railing
n o n e
____________________________________________________________________________________________
More than
eight feet
Less than Six feet
Fence and
Canopy
______________________________________________________________________________________
Six feet or more but not more than one-fourth the height of construction
Fence and
Canopy
________________________________________________________________________________________
Six feet or more, but between eight feet one-fourth to one half the height of construction
Fence
________________________________________________________________________________________
Six feet or more but exceeding one-half the construction height
None
____________________________________________________________________________________________
Note: All protective devices shall include appropriate lights and warning signs.